Release of PVTsim 17.3
July 15th, 2008
Updates and Bug fixes from PVTsim 17.2 to 17.3
- Error corrected in saturation point logic that might cause failure of regression when including swelling data.
- Limit on number of cells in slimtube option increased to 2000. Time step and cell output frequency introduced.
- Tabulated saturation pressure in Prosper/Mbal interface changed to always be the higher one (relevant for temperature tabulation points with two saturation point pressures).
- Plus regression erroneously changed the Peneloux parameter of CO2 marginally. This caused problems e.g. in MMP simulations with a CO2 "No Plus" fluid as injection gas.
- Error corrected in DepoWax causing the simulation results to be the same after all time steps.
- The Save Phase option erroneously assigned asphaltene components an asphaltene fraction of 0.0. Corrected to be 1.0.
- Error corrected in weaving option for asphaltene components.
- Too low a thickness of laminar film layer in DepoWax caused too much wax deposition